SolaX inverter

The SolaX inverter is connected to the Currentt Navigator to read production data and control the system. The supported models are grid-tied (string) inverters without a battery.


⚙️ How it works​

The Currentt Navigator communicates with the SolaX inverter via Modbus. The Navigator reads production data, power values and status information, and can control the power output of the inverter.

This can be done in two ways: via a wired RS-485 connection on the COM port of the inverter (Modbus RTU), or via the local network using a Pocket dongle (Modbus TCP).

Grid-tied inverters

The supported SolaX models (X1-MINI, X1-BOOST, X1-SMART and X3-MIC) are grid-tied inverters without a battery connection. No battery data is read as a result.


🔌 Connection options​

Connect the inverter to the Currentt Navigator using one of the methods below.

Option 1: Modbus RTU (RS-485)​

A wired connection via an RS-485 cable between the COM port of the inverter and the RS-485 Modbus connection on the Currentt Navigator. This is a direct physical connection and does not require network infrastructure.

PropertyValue
ConnectionRS-485 cable (CAT6 SFTP)
Internet requiredNo
Suitable for controlYes
SolaX Cloud keeps workingYes

Option 2: Modbus TCP (local network)​

A connection via the local network using a SolaX Pocket dongle. The dongle and the Currentt Navigator must both be connected to the same network.

PropertyValue
ConnectionEthernet or WiFi (via Pocket dongle)
Internet requiredNo
Suitable for controlYes
SolaX Cloud keeps workingYes
Not every dongle supports Modbus TCP

Only the Pocket WiFi V3.0-P, Pocket WiFi+LAN and Pocket WiFi+4GM support Modbus TCP. The older Pocket LAN and Pocket WiFi 2.0 do not offer Modbus TCP. In that case, use Modbus RTU.


⚖️ Comparison​

Modbus RTUModbus TCP
ConnectionRS-485 cableNetwork (via Pocket dongle)
Internet requiredNoNo
Physical cableYes (RS-485)No (when using WiFi)
Additional hardwareNoPocket WiFi V3.0-P or Pocket WiFi+LAN
SolaX Cloud keeps workingYesYes
Suitable for controlYesYes

✅ Compatible models​

ModelPowerTypeModbus RTUModbus TCP
X1-MINI G30.6 – 3.6 kWSingle-phaseYesYes
X1-MINI G40.6 – 3.3 kWSingle-phaseYesYes
X1-BOOST G42.5 – 6 kWSingle-phaseYesYes
X1-SMART G25 – 10 kWSingle-phaseYesYes
X3-MIC G23 – 15 kWThree-phaseYesYes