Solis inverter

The Solis inverter is connected to the Currentt Navigator to read production data and control the system. On hybrid inverters (S6-EH series), the battery is automatically included as well.

Beta integration

Support for Solis is currently in beta. If anything does not work as expected, please contact customer support.


⚙️ How it works​

The Currentt Navigator communicates with the Solis inverter via Modbus. The Navigator reads production data, power values and status information, and can control the power output of the inverter. On a hybrid inverter with a connected battery, the battery data is read via the same connection.

Hybrid inverters

On a hybrid inverter with a connected battery, all battery data (state of charge, charge and discharge power, status) is automatically read via the same connection. See also the Solis battery guide.

Power limiting works differently on Solis

On Solis, controlling the inverter power only curtails PV production once the battery is fully charged (100%). Below 100%, the excess is absorbed by the battery instead of being limited.


🔌 Connection options​

Connect the inverter to the Currentt Navigator using one of the methods below.

Option 1: Modbus RTU (RS-485)​

A wired connection via an RS-485 cable between the COM port of the inverter and the RS-485 Modbus connection on the Currentt Navigator. This is a direct physical connection and does not require network infrastructure.

PropertyValue
ConnectionRS-485 cable (CAT6 SFTP)
Internet requiredNo
Suitable for controlYes
SolisCloud keeps workingYes

Option 2: Modbus TCP (local network)​

A connection via the local network using the Solis DataLogger S2-WL-ST. The data logger and the Currentt Navigator must both be connected to the same network.

PropertyValue
ConnectionEthernet or WiFi (via data logger)
Internet requiredNo
Suitable for controlYes
SolisCloud keeps workingNo
Modbus TCP breaks the SolisCloud connection

When you enable Modbus TCP on the DataLogger S2-WL-ST, the data logger loses its connection to SolisCloud. You therefore have to choose between local Modbus TCP communication and monitoring via SolisCloud. Do you want to keep both? Then use Modbus RTU.


⚖️ Comparison​

Modbus RTUModbus TCP
ConnectionRS-485 cableNetwork (via data logger)
Internet requiredNoNo
Physical cableYes (RS-485)No (when using WiFi)
Additional hardwareNoDataLogger S2-WL-ST
SolisCloud keeps workingYesNo
Suitable for controlYesYes

✅ Compatible models​

ModelPowerTypeModbus RTUModbus TCP
S6-EH3P10K10 kWHybrid (three-phase)YesYes
Other S6-EH hybrid modelsto be determinedHybridYesYes
Tested Solis equipment

This integration has been validated against a Solis hybrid inverter paired with a battery:

  • Hybrid inverter: Solis S6-EH3P10K (three-phase)
  • Battery: high-voltage pack reporting through the inverter's BMS

Other Solis hybrid models and battery brands may work but are not yet verified. If your installation differs or you run into issues, please contact customer support.